BTS2048-UV

Spectrometer by Gigahertz-Optik

Note: Your Quotation Request will be directed to Gigahertz-Optik.

The BTS2048-UV from Gigahertz-Optik is a CCD Spectroradiometer that has a spectral range of 190 nm - 430 nm. It has an electronic shutter with an optical bandwidth of 0.8 nm and a peak wavelength of ± 0.05 nm. This device (also known as BiTec Sensor) is a combination of a back-thinned CCD spectrometer and a Si photodiode that has a resolution of 2048 pixels and pixel resolution of 0.13 nm/pixel. It has a 16-bit ADC with an instruction cycle time of 25 ns and integration time of 2 μs - 60 s. This spectroradiometer has a baseline noise of 5 cts and signal-to-noise ratio of 5000. It has a dynamic range above 9 magnitudes and supports mathematical online band-pass correction.

The BTS2048-UV has one-stage thermoelectric cooler and a completely linearized chip with linearity of greater than 99.6 %. It has a 32-bit microprocessor for device control, an 8-bit microprocessor for photodiode control, and can be controlled via ethernet or USB 2.0 interfaces for data transfer. This spectroradiometer supports 3 measurement modes: standard, out of range stray light corrected, & stray light corrected bandpass and has a measurement time of 0.1 ms - 6000 ms. It requires a DC supply voltage of 5 V and consumes 700 mA of current. This device is available in a module that measures 103 mm (L) x 107 mm (W) x 52 mm (H) and is ideal for design applications & integration in test systems for front-end and back-end LED testing.

Product Specifications

View similar products

Product Details

  • Part Number
    BTS2048-UV
  • Manufacturer
    Gigahertz-Optik
  • Description
    190 nm - 430 nm, CCD Spectroradiometer for LED Testing Applications

Applications

  • Applications
    Design Applications, Front-end and Back-end LED Test Measurements

Connections & Interface

  • Interface
    USB 2.0, Ethernet, RS232, RS485

General Parameters

  • Measuring Techniques
    Irradiance, CCD Spectroscopy, UV Spectroscopy
  • Spectrometer Type
    Tripod Base
  • Wavelength Range
    190 to 430 nm
  • Spectral Resolution
    0.8 nm
  • Spectrum Band
    UV
  • A/D Resolution
    16 Bit
  • Integration Time
    2 µs to 60 s
  • Stray Light :
    <0.0001
  • Pixels
    2048 pixels
  • Dynamic Range
    >9 Magnitudes
  • Image Sensor
    CCD
  • Noise Ratio
    5000:1
  • Supply Voltage
    5 VDC
  • Trigger Modes
    Rising/falling edge
  • Wavelength accuracy
    ±0.05 nm
  • Note
    Measurement Time: 0.1 to 6000 ms

Temperature

  • Operating Temperature display
    10 to 30 Degree C
  • Storage Temperature
    -10 to 50 Degree C

Physical Properties

  • Weight
    500 g
  • Dimension
    103 x 107 x 52 mm (L x W x H)

Technical Documents

Click to view more product details on manufacturer's website
Need Help Finding a Product?

Looking for a Product or Supplier?