PoliSpectra® M116

Spectrometer by HORIBA

Note: Your Quotation Request will be directed to HORIBA.

The PoliSpectra® M116 from HORIBA is a UV-NIR Spectrometer that has a spectral range of 185 nm - 1050 nm. It has a back-illuminated CMOS sensor which can be configured with 8,16 or 32 fiber input channels. This spectrometer has a spectral dispersion of 34.6 nm/mm (0.38 nm/pixel), wavelength accuracy of 0.1 nm, and spectral resolution of 1.25 nm (8-channel) & 1 nm (16,32-channel). It has a focal length of 116 mm (8-channel) and an f-number of F/2.3. This spectrometer has a stray light of 0.1% and smile & keystone of 1.5 pixel.

The CMOS sensor has an electronic rolling shutter that delivers a frame rate of 94 fps (HDR mode) & 188 fps (STD mode). It has a resolution of 2048 x 512 pixels with a pixel size of 11 µm x 11 µm. The sensor has a 16-bit (HDR) & 12-bit (STD mode) ADC and pixel height of 5.6 mm. It has a quantum efficiency of 77% (at 250 nm) & 95% (at 560 nm) and full well capacity of 80 ke- (HDR mode). The sensor has a readout noise of 1.6 e- and dynamic range of 93.9 dB. It has a nonlinearity of 1.8% (HDR mode) and 0.9% (STD mode).

The PoliSpectra® M116 can be controlled via a USB 3.0 communication interface and uses LabVIEWTM acquisition software. This spectrometer requires an AC supply voltage of 90 - 240 V and is available in a robust package that measures 156.4 (L) mm x 150.9 (W) mm x 184.2 (H) mm. It is ideal for multitrack spectroscopy, fluorescence, emission and reflectance applications and semiconductor applications to life sciences such as quality control, light source calibration monitoring, plasma monitoring, and blood/DNA multisampling applications.

Product Specifications

View similar products

Product Details

  • Part Number
    PoliSpectra® M116
  • Manufacturer
    HORIBA
  • Description
    185 nm - 1050 nm, UV - NIR Spectrometer for Industrial & Spectroscopy Applications

Applications

  • Applications
    MultiTrack Spectroscopy, Fluorescence, Emission and Reflectance

Connections & Interface

  • Interface
    USB 3

General Parameters

  • Measuring Techniques
    Fluorescence Spectroscopy, NIR Spectroscopy, Reflectance, UV Spectroscopy, Plasma Spectroscopy
  • Spectrometer Type
    Benchtop
  • Wavelength Range
    185 to 1050 nm
  • Spectral Resolution
    1 nm
  • Spectrum Band
    UV-NIR
  • Stray Light :
    < 0.1% (typical)
  • Slitwidth
    22 µm
  • Pixels
    2048 x 512
  • Aperture(f-number)
    F/2.3
  • Digitizer Speed
    12 bit, 16 bit
  • Dynamic Range
    64 dB, 68 dB, 95 dB
  • Pixels Size
    11 µm x 11 µm
  • Image Sensor
    Scientific CMOS Image Sensor
  • Input Focal length
    116 mm
  • Power Requirements
    90-264 VAC, 47–63 Hz
  • Quantum Efficiency
    77%, 95%
  • Readout Noise
    1.6 e-, 1.3 e-
  • Relative Humidity
    < 70%
  • Wavelength accuracy
    0.1 nm
  • Note
    8 Channel, 16 Channel, 32 Channel

Temperature

  • Operating Temperature display
    15 to 40 Degree C
  • Storage Temperature
    25 to 45 Degree C

Technical Documents

Click to view more product details on manufacturer's website
Request a Quote