FHO3000-D30

Optical Time Domain Reflectometer (OTDR) by Grandway Telecom

Note: Your Quotation Request will be directed to Grandway Telecom.

The FHO3000-D30 from Grandway Telecom is a Mini Optical Time Domain Reflectometer (OTDR) that operates at a wavelength of 1310 nm or 1550 nm. It has a measuring range above 100 km and dynamic range of 30 dB. This OTDR has an event dead zone of 1 m and attenuation dead zone of 5 m. It has a pulse width of 3 ns - 20 µs and linearity of ± 0.03 dB/dB. This OTDR has up to 128000 sampling points with a sampling resolution of 0.05 m and loss threshold of 0.01 dB. It has a distance resolution of 0.01 m and loss resolution of 0.001 dB. 

The FHO3000-D30 has an index of refraction of 1.2 - 1.7 and a memory capacity of 80000 groups curve. It has a 5-inch TFT-LCD touchscreen display and includes a power adapter, charge cord & lithium battery. This OTDR can be controlled via 2 type A USB and 1 micro USB interfaces and supports FC/LC/SC adapters. It has a visual fault locator that consumes 10 mW of power and an optical power meter with test range from -60 dBm to 5 dBm. This OTDR is available in a compact package that measures 195 mm x 141 mm x 44 mm.

Product Specifications

Product Details

  • Part Number
    FHO3000-D30
  • Manufacturer
    Grandway Telecom
  • Description
    1310/1550 nm Mini Optical Time Domain Reflectometer

Environmental Conditions

  • Operating Temperature
    -10 to 50 Degree C
  • Storage Temperature
    -20 to 70 Degree C

Connections & Interface

  • Interface
    USB
  • Optical Connector
    FC

General Parameters

  • Equipment Type
    Multifuntional/Modular
  • Event Dead Zone
    1 m
  • Attenuation Dead Zone
    5 m
  • Optical Wavelength
    1310 to 1550 nm
  • Battery Body Material
    Lithium
  • Battery Capacity
    7.4 V / 3300 mAh
  • Display
    5 Inch TFT-LCD
  • Distance Accuracy
    ±(1m + test distance x 3 x 10-5 + 0.05 m
  • Distance Resolution
    0.01 m
  • Fiber Type
    Single Mode
  • IOR Setting
    1.2000 to 1.7000
  • Battery working and charging time
    6 Hr (Operating), 3.5 Hr (Charging)
  • Linearity
    ±0.03 dB
  • Dynamic Range
    28 to 30 dB
  • Loss Resolution
    0.001 dB
  • Loss Threshold
    0.01 dB
  • Memory Capacity
    80000 groups curve
  • Pulse Width
    3 ns to 20 µs
  • Test Range
    -60 to 5 dBm
  • Sampling Point
    128000 points
  • Sampling Resolution
    0.05 m
  • VFL Output Power
    10 mW
  • VFL(Launching Mode)
    CW/2Hz

Physical Properties

  • Dimension
    195 x 141 x 44 mm
  • Weight
    0.9 kg

Technical Documents

Click to view more product details on manufacturer's website
Advertisement
Request a Quote