Polarization Extinction Ratio Meters

21 Polarization Extinction Ratio Meters from 11 manufacturers listed on GoPhotonics

A Polarization Extinction Ratio (PER) Meter is an optical test instrument used to measure how well light is polarized, especially in fiber optic systems. Polarization Extinction Ratio Meters from the leading manufacturers are listed below. Use the filters to narrow down on products based on your requirement. Download datasheets and request quotes for products that you find interesting. Your inquiry will be directed to the manufacturer and their distributors in your region

21 Polarization Extinction Ratio Meters from 11 Manufacturers
21 Products from 11 Manufacturers
Page 1 of 2
Polarization Extinction Ratio Meter for Troubleshooting Applications

Product Specs

Interface:
USB
Measurement Type:
Rotating Polarizer
Wavelength Range:
850 to 1650 nm
Polarization Extinction Ratio (PER) Range:
30 to 35 dB
Dynamic Range:
47 dB
Input Optical Power:
50 µW to 1 mW
PER Accuracy:
±1 dB
PER Resolution:
0.01 dB
Package:
Handheld
more info
400 nm - 700 nm, Polarization Extinction Ratio Meter for Military Applications

Product Specs

Interface:
USB Type B
Measurement Type:
Rotating Polarizer
Wavelength Range:
400 to 700 nm
Polarization Extinction Ratio (PER) Range:
0 to 40 dB
Input Optical Power:
13 dBm
PER Accuracy:
<0.5 dB
PER Resolution:
0.1 dB (Display), 0.01 dB (USB)
Package:
Benchtop
more info
357 nm - 2400 nm, Polarization Extinction Ratio Meter for Laboratory Applications

Product Specs

Interface:
RS-232C
Measurement Type:
Polarization Beam Splitter (PBS)
Wavelength Range:
357 to 2400 nm
Polarization Extinction Ratio (PER) Range:
0 to 50 dB
Dynamic Range:
50 dB
Input Optical Power:
0.05 to 380 mW
PER Accuracy:
1 dB
PER Resolution:
0.01 dB
Package:
Handheld
more info
400 nm - 1700 nm, Polarization Extinction Ratio Meters for Research Applications

Product Specs

Interface:
RS-232
Measurement Type:
Polarization Beam Splitter (PBS)
Wavelength Range:
400 to 1700 nm
Polarization Extinction Ratio (PER) Range:
30 to 50 dB
Dynamic Range:
20 to 40 dB
Input Optical Power:
-40 to 10 dBm
PER Accuracy:
<±0.1 dB, <±0.3 dB, <±1 dB
PER Resolution:
0.01 dB, 0.001 dB
Channels:
Multi
Package:
Benchtop, Rackmount
more info
600 nm - 1620 nm, Polarization Extinction Ratio Meter for Monitoring Applications

Product Specs

Interface:
USB, RS-232, Ethernet, GPIB
Measurement Type:
Rotating Polarizer
Wavelength Range:
600 to 1620 nm
Polarization Extinction Ratio (PER) Range:
0 to 50 dB
Input Optical Power:
-30 to 10 dBm
PER Accuracy:
±0.15 dB
PER Resolution:
0.1 dB
Channels:
Dual
Package:
Rackmount
more info
840 nm - 1630 nm, Polarization Extinction Ratio Meter for Splicing Applications

Product Specs

Interface:
RS-232
Measurement Type:
Rotating Polarizer
Wavelength Range:
840 to 1630 nm
Polarization Extinction Ratio (PER) Range:
0 to 50 dB
Dynamic Range:
40 to 50 dB
Input Optical Power:
5 to 20 dBm
PER Accuracy:
<±0.1 dB, <±0.3 dB, <±1 dB
PER Resolution:
0.01 dB, 0.001 dB
Channels:
Single, Dual, Quad, Multi
Package:
Benchtop, Rackmount
more info
1260 nm - 1650 nm, Polarization Extinction Ratio Meter for IOC Measurements

Product Specs

Interface:
USB, RS-232, Ethernet, GPIB
Measurement Type:
Polarization Beam Splitter (PBS)
Wavelength Range:
1260 to 1650 nm
Polarization Extinction Ratio (PER) Range:
0 to 50 dB
Dynamic Range:
>50 dB
Input Optical Power:
-30 to 10 dBm
PER Accuracy:
±0.15 dB
PER Resolution:
0.1 dB
Package:
Rackmount
more info
Polarization Extinction Ratio Meter for Measurement Applications

Product Specs

Interface:
USB, UART
Measurement Type:
Polarization Beam Splitter (PBS)
Wavelength Range:
600 to 1650 nm
Polarization Extinction Ratio (PER) Range:
0 to 52 dB
Input Optical Power:
-65 to 11 dBm
PER Accuracy:
0.05 dB
PER Resolution:
0.01 dB
Package:
Module with Connectors
more info
Polarization Extinction Ratio Meter for Measurement Applications

Product Specs

Interface:
GPIB, RS232, USB
Measurement Type:
Rotating Polarizer
Wavelength Range:
1260 to 1640 nm
Polarization Extinction Ratio (PER) Range:
0 to 50 dB
Dynamic Range:
0 to 50 dB
Input Optical Power:
-40 to 10 dBm
PER Accuracy:
±0.3 dB
PER Resolution:
0.1 dB
Channels:
Single
Package:
Benchtop
more info
Polarization Extinction Ratio Meter for Fiber Optic Ring Systems

Product Specs

Interface:
RS-232
Measurement Type:
Polarization Beam Splitter (PBS)
Wavelength Range:
600 to 1635 nm
Polarization Extinction Ratio (PER) Range:
30 to 45 dB
Dynamic Range:
30 to 45 dB
Input Optical Power:
-40 to 10 dBm
PER Accuracy:
<±0.1 dB, <±0.3 dB, <±1 dB
PER Resolution:
0.01 dB, 0.001 dB
Package:
Benchtop
more info
1 - 10 of 21 Polarization Extinction Ratio Meters
Advertisement
Polarization Extinction Ratio Meter Manufacturers

Filters

Manufacturers

Polarization Extinction Ratio (PER) Range (dB)

Apply

Input Optical Power (dBm)

Apply

PER Accuracy (dB)

Apply

PER Resolution (dB)

Apply

Wavelength Range (nm)

Apply

Dynamic Range (dB)

Apply

Interface

More

Package

More

Country