| New Photonics Products this Week |
|
|
| 1310/1550 nm Reflectometer for Reflection & Insertion Loss Measurements | |
Reflectometer
from Yokogawa Test & Measurement Corporation
|
| The AQ7421 from Yokogawa Test & Measurement Corporation is a High-Resolution Reflectometer that delivers clean and accurate measurements for testing optical components and devices. This device provides a clear analysis of waveguide reflections & propagation loss, capturing sharp peaks and scattered light to enable direct calculation of propagation loss from return loss distribution |
| |
Download Datasheet
Product Details | |
|
|
|
| 1.2 µm - 8 µm, Broadband Fiber-Coupled MIR Thermal Emitter | |
Infrared Emitter
from NLIR
|
| The FIBER Light Source from NLIR is a broadband MIR thermal emitter with an optical bandwidth of 1.2 µm - 8.0 µm. It delivers an output power of 5 mW (in a 500 µm fiber) and is stabilized for a minimum lifetime of 1800 hours. This light source is ideal for applications such as foil characterization in transmission measurement systems & optical coating characterization. |
| |
Download Datasheet
Product Details | |
|
|
|
| 450 nm Fiber-Coupled Laser Diode | |
Laser Diode
from PhotonTec Berlin
|
| The M450±10-5-F105/22-C1S-P from PhotonTec Berlin is a Laser Diode with a wavelength of 450 nm. It delivers an output power of 5 W and has a spectral width below 10 nm (FWHM). This laser diode has a slope efficiency of 1.72 W/mA and power conversion efficiency of 38%. It has a fiber pigtailed core diameter of 105 μm and numerical aperture of 0.22. This fiber-coupled laser diode supports an SMA fiber connector with fiber lengths of 1 m and 5 m. |
| |
Download Datasheet
Product Details | |
|
|
|
| 770 nm Single Frequency Laser Diode for Metrology Applications | |
Laser Diode
from TOPTICA EAGLEYARD
|
| The miniECL series from TOPTICA EAGLEYARD is a Single Frequency Laser Diode that operates at a center wavelength of 770 nm. It delivers an output power of up to 18 W and has a linewidth (FWHM) of 0.1 MHz. This external cavity laser diode has a monitor detector responsivity of 10 μA/mW and is ideal for spectroscopy, metrology & quantum technology applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| 193 nm Laser Mirror for Ultraviolet Laser Applications | |
Optical Mirror
from OPTOMAN
|
| The PP-UVFS-25.4-6.35-LLM290 from OPTOMAN is a Laser Mirror that operates at a wavelength of 193 nm. It has a diameter of 25.4 mm, thickness of 6.35 mm, and chip size of less than 0.2 mm. This deep UV mirror has a clear aperture of 22 mm and surface quality of 10-5 S-D (scratch-dig) (S1/S2). It has a maximum surface flatness of 1/10th of wavelength (at 633 nm) and parallelism of 10 arcsec. This mirror is ideal for ultraviolet laser applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| Opto-Mechanical Software for Optimization of illumination and Optical Systems | |
Optical Design Software
from Lambda Research Corporation
|
| The TracePro from Lambda Research Corporation is an Opto-Mechanical Software that facilitates the design, analysis, and optimization of optical & illumination systems. It offers flexible solid modeling capabilities for users to import CAD & lens design files and is ideal for a wide range of applications, including lightpipe design, displays, stray light analysis, solar collectors, and UV sterilization. |
| |
Download Datasheet
Product Details | |
|
|
|
| 1560 nm Femtosecond Laser for Metrology Applications | |
Laser
from Cycle GmbH
|
| The SOPRANO-Mini from Cycle GmbH are Erbium Femtosecond Lasers that operate at a wavelength of 1560 nm. They deliver an average output power of up to 200 mW and have a wavelength accuracy of ± 10 nm. These lasers are ideal for THz time-domain spectroscopy, seeder for Titanium: Sapphire laser amplifier, two-photon microscopy, metrology, and spectroscopy applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| Sapphire Window for Precision Imaging Applications | |
Optical Window
from Meller Optics, Inc
|
| The MSPW050/010M from Meller Optics, Inc is a Sapphire Window that has C-Plane orientation. It has a diameter of 0.5 inches and thickness of 1 mm with tolerance of ± 0.1 mm. This window has a clear aperture of 85% of the diameter face and surface quality of 20-10 S-D (scratch-dig). It is ideal for precision imaging optics, polarization sensitive optics, Near-Ultraviolet wavelength optics, reticles, and refractometer window applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| Multi-Color LED Ring Light for Cameras | |
LED
from IMPERX
|
| The Non-PoE LED Ring Light from IMPERX is a Multi-Color Ring Light LED that has a peak light intensity of 20k lux (at 0.3 m) and 15k lux (at 0.5 m). It has a working distance of 0.5 m - 5 m and is ideal for applications that require controlled light patterns, special wavelength illumination, dynamic lighting capability with fast on/off or intensity changes, camera-synchronized strobe operation, and highly consistent output over time & temperature variations. |
| |
Download Datasheet
Product Details | |
|
|
|
| 400 nm - 1700 nm, Avalanche Photodiodes for LiDAR Applications | |
Photodetector
from Laser Components
|
| The A-CUBE-S1500-01 from Laser Components is a Silicon Avalanche Photodetector that operates at a wavelength of 400 nm - 1000 nm. It has a responsivity of 270 MV/W (540 nm), 400 MV/W (650 nm), and 500 MV/W (905 nm). This APD is ideal for APD evaluation, range finding, LiDAR, optical communication systems, spectroscopy, fluorescence, and medical applications. |
| |
Download Datasheet
Product Details | |
|
|
| Sponsored by Yokogawa | | See the signal, not the noise | | The AQ7421 High-Resolution Reflectometer captures true reflection profiles with high sensitivity and resolution for IL/RL diagnostics, minimizing spurious effects. Ideal for transceiver, connector, and fiber assembly evaluation. Click here to learn more. | | | |
|
|
| 560 nm Photoresistor for Light/Dark Switching Applications | |
Photoresistor
from Sicube Photonics
|
| The GL12528 from Sicube Photonics is a Photoresistor that has a spectral peak of 560 nm. It has a photo resistance of 8 kOhms - 20 kOhms, dark resistance of 2 MOhms, and resistance illumination coefficient of 0.6. This photoresistor has a rise & decay time of 30 ms and diameter of 12 mm. It is ideal for light-detection circuits and light or dark activated switching applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| 560 nm Photoresistor for Camera & Light Control Applications | |
Photoresistor
from ShenZhen HaiWang Sensor
|
| The MJ11528 from ShenZhen HaiWang Sensor is a Photoresistor that has a spectral peak of 560 nm. It has a light resistance of 20 kOhms - 30 kOhms (at 10 lux) and dark resistance of 3 MOhms. This photoresistor is ideal for camera, automatic metering, photoelectric control, alarm industrial control, light control switch, light control lamp, electronic toy, and indoor light control applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| 560 nm Photoresistor for Light Detection Systems | |
Photoresistor
from Nanyang Lida Optic-electronics
|
| The GL 7516 from Nanyang Lida Optic-electronics is a Photoresistor with a wavelength of 560 nm. It has a light resistance of 4 kOhms - 10 kOhms, dark resistance of 0.5 MOhms, and resistance illumination coefficient of 0.65. This photoresistor requires an AC supply voltage of 150 V and consumes 90 mW of power. It is available in a resin-coated plastic package that measures Ø7 mm x 5.9 mm x 36 mm and is ideal for light detection system applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| 580 nm NIR/VIS Photoresistor for Industrial Applications | |
Photoresistor
from Advanced Photonix
|
| The NSL-11932 from Advanced Photonix is a Photoresistor that has a spectral peak of 580 nm. It has a light resistance of 400 Ohms - 1600 Ohms and minimum dark resistance of 100 kOhms. This photoresistor requires an AC supply voltage of 60 V and consumes 400 mW of power. It is available as a TO-8 hermetic photocell assembled in a black housing and is ideal for industrial applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| 400 nm - 2500 nm, Laser Line Tunable Filters for Spectroscopy Applications | |
Optical Filter
from Photon etc.
|
| The LLTF Contrast from Photon etc. are Laser Line Tunable Filters with a spectral range of 400 nm - 2500 nm. They have a spectral bandwidth (FWHM) of 0.15 nm - 2300 nm and an out of band rejection of less than 60 dB. These filters have a wavelength selection accuracies below 0.33 nm, 0.66 nm & 0.13 nm and are ideal for tunable laser generation & cleanup filter for spectroscopy applications. |
| |
Download Datasheet
Product Details | |
|
|
|
|
|
|
|
|
| 500 nm - 1200 nm, Mini-Chrom Monochromator for Analytical Applications | |
Monochromator
from Edmund Optics
|
| The 53-954 from Edmund Optics is a Mini-Chrom Monochromator that operates at a wavelength of 500 nm - 1200 nm. It has a wavelength accuracy of ± 0.2% and reproducibility of ± 0.15%. This manual monochromator is ideal for a variety of sophisticated analytical & biomedical equipment like clinical chemistry analyzers, HPLC detectors, and UV-VIS-NIR spectrophotometers. |
| |
Download Datasheet
Product Details | |
|
|
|
|
|
|
|
|
| 0.33 Megapixel SWIR Camera for Security & Surveillance Applications | |
Scientific & Industrial Camera
from New Imaging Technologies
|
| The WiDy NaNo 640 from New Imaging Technologies is a 0.33 Megapixel SWIR Camera that has a Video Graphics Array (VGA) resolution of 640 (H) x 512 (V) pixels. It has a spectral response of 0.9 µm - 1.7 µm in a 1" optical sensor format that delivers a full frame rate of up to 100 Hz (100 fps). This HDR camera has a dynamic range of 120 dB and is ideal for security & surveillance applications. |
| |
Download Datasheet
Product Details | |
|
|
|
| 632 nm Fizeau Interferometer for Optical System Measurement | |
Interferometer
from Plano Optics Private Limited
|
| The FIFM-100H from Plano Optics Private Limited is a Fizeau Interferometer with a wavelength of 632.8 nm. It delivers an output power of 2 mW and has clear apertures of 60 mm & 100 mm. This interferometer has a transmission flat accuracy of lambda/10 and lambda/20. It is ideal for testing the flatness & sphericity of surfaces, measuring radii, and evaluating the performance of optical systems. |
| |
Download Datasheet
Product Details | |
|